4LP350X X50FT / 4FM7002

Description
# LP350X
RECOMMENDED FOR: Liquid or gaseous propane, butane or any combination of these two mixtures. Can be used for natural gas (not to exceed 50 psi) under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit). CAUTION: Not recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744–5070 for inspection and assembly testing information. Warning: Do not convey LP Gas over +140°F (60°C).
– CAUTION: Not recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744–5070 for inspection and assembly testing information.
– Meets standards: UL No. 21, CAN/CGA-8.1-M86, NFPA 58 Section 8-3.5.
– Design Factor: 5:1
Additional information
| Vacuum (In. Hg) | 30 |
|---|---|
| Continuous Operating Temperature Range | -40°F to +180°F |
| Minimum Bend Radius (in) | 3 |
| Minimum Bend Radius (mm) | 76 |
| Min. Burst Pressure (psi) | 1750 |
| Hose Inside Diameter (in) | 0.25 |
| Hose Inside Diameter (mm) | 6.4 |
| Hose Outside Diameter (in) | 0.58 |
| Hose Outside Diameter (mm) | 14.7 |
| Inside Diameter (in) | 1.5 – 3 |
| Inside Diameter (mm) | 38.1 – 76.2 |
| Working Pressure (psi) | 350 |
| Length (m) | 15.2 |
| Outside Diameter (in) | 2.25 – 3.88 |
| Outside Diameter (mm) | 38.1 – 76.2 |
| Use | Industrial Hose |
| Color | Black |
| Reinforcement | 3-braid, textile |
| Tube | Chloroprene – Type A. High oil resistance. |
| Construction: Cover | Chloroprene – Type A, Type A (Chloroprene). Black. |
| Standards | CAN/CGA-8.1-M86. NFPA 58, Section 8-3.5. Underwriters Laboratories Standard No. 21. (Applies to all sizes)., Underwriters Laboratories Standard No. 569. (Applies to hose assemblies only). |
| Recommended For | Liquid or gaseous propane, butane or any combination of these two mixtures up to 350 psi rated working pressure. Can be used for natural gas under certain conditions such as: open/outside areas and well ventilated factory buildings (if local building codes permit). Not recommended for residential or office buildings. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information. Meets UL Standard #21, CAN/CGA-8.1-M86, NFPA 58, Section 8-3, 5. |
| Caution | Not recommended for residential, office buildings or as fuel line hose on compressed natural gas vehicles. Contact Denver Product Application (303) 744-5070 for inspection and assembly testing information., This hose should not be used for liquid LPG or in UL approved appliances such as barbecue grills. |
| Customer Pack | 1 |
| Weight (lbs.) | 6.43 |
| Includes Switch Port | false |
| Max. Working Pressure | 350 |
| Max. Working Pressure (Bar) | 24.1 |
| Construction: Design Factor | 5:1 |
| Construction: Reinforcement | High tensile synthetic textile cord. |
| Construction: Tube | Type C (Nitrile). Black. |
| Notes | Application Note: No LP350 hose assemblies 60" or longer allowed per UL requirement. |